Red Hat ENTERPRISE LINUX 4.5.0 - Instrukcja Użytkownika Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 21
22
EMC PowerPath for Linux Version 4.5 and Point Releases Release Notes
Technical Notes
PowerPath and the CLARiiON admsnap Utility
Take note of the following if you use the CLARiiON admsnap utility
with PowerPath devices.
For all versions of the admsnap utility, set the
PP_SHOW_CLAR_OWNING_SP environment variable to false to
suppress the display of default and current SP data:
PP_SHOW_CLAR_OWNING_SP=false
For admsnap utility version 2.4.0.0.3 or less:
Set the
PP_DEFAULT_STORAGE_SYS environment variable to
clariion to restrict the class of devices displayed by the
powermt utility to CLARiiON devices:
PP_DEFAULT_STORAGE_SYS=clariion
Use a native PowerPath name (for example, /dev/sde) to start
or activate an
admsnap session when a file system is mounted
on a PowerPath device. You cannot use a PowerPath pseudo
device name (for example,
/dev/emcpowere) to start or
activate a session when a file system is mounted on a
PowerPath device.
Przeglądanie stron 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28

Komentarze do niniejszej Instrukcji

Brak uwag