3.2.2 Checking the device-mapper multipath Status and Created Devices
Check the path status using the "multipath -ll" command. Check that the recognized status of the devices for
all the paths that are assigned to the server is normal.
Multipath is in normal status (This example shows when two paths are used to connect to the ETERNUS
DX80)
Check that multipathing is configured in the two block devices and "active ready" is displayed for each path
status.
# multipath -ll
mpath2 (3600000e00d00000000000f7e00010000) dm-1 FUJITSU,ETERNUS_DXL
[size=10G][features=1 queue_if_no_path][hwhandler=0][rw]
\
_
round-robin 0 [prio=50][active]_ round-robin 0 [prio=50][active]
\_ 4:0:0:1 sde 8:64 [active][ready]
\_ round-robin 0 [prio=10][enabled]
\_ 3:0:0:1 sdc 8:32 [active][ready]
:
:
:
When the path status is normal,
"[active][ready]" is displayed.
Two block device names are displayed
for a two-path configuration.
Multipath (the "3:0:0:X" side) is in error status (This example shows when two paths are used to connect to
the ETERNUS DX80)
# multipath -ll
mpath2 (3600000e00d00000000000f7e00010000) dm-1 FUJITSU,ETERNUS_DXL
[size=10G][features=1 queue_if_no_path][hwhandler=0][rw]
\_ round-robin 0 [prio=50][active]
\_ 4:0:0:1 sde 8:64 [active][ready]
\_ round-robin 0 [prio=0][enabled]
\_ 3:0:0:1 sdc 8:32 [failed][faulty]
:
:
The status for the failed path
is "[failed][faulty]".
Chapter 3 For Red Hat Enterprise Linux 5
3.2 Checking the device-mapper multipath
16
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
(Fibre Channel/FCoE/iSCSI/SAS) for Linux
Copyright 2015 FUJITSU LIMITED
P3AM-3912-21ENZ0