F5 SDC Troubleshooting Guide
Proprietary and Confidential Information of F5 Networks
11
scripting errors.
configuration manager.
Cause – Scripting Errors
One of the initialization/engineering/health monitoring scripts has errors, causing the SPF to
crash.
Resolution – Verifying Scripts
You need to correct the faulty script.
Note: Usually you can access the scripts (SDC Life Cycle; Health Monitoring, Engineering)
from the Web UI. However, because FEP/CPF are not running, they cannot accept any
configuration changes
To correct the scripts:
1. Shut down all SDC processes (including config manager).
2. Locate and correct the script errors in the most recent flowManager.xml file (of
each FEP/CPF).
3. Check the scripts in the following XML hierarchy:
- FlowManagerMgmt/Administration/PostSystemInit
- FlowManagerMgmt/Administration/StatusCheck/Condition+CheckStatus
Cause – Configuration Manager
The SDC component (CPF) is unable to retrieve its configurations from the config manager.
By default, the connection between each SDC component and the config manager is done
using a multicast auto discovery mechanism.
When this occurs the following message is the last message in the log file after the component
was started:
2013-12-15 09:19:17,123 INFO [] Starting beans in phase 2147483647 [main_1]
[DefaultLifecycleProcessor$LifecycleGroup.start()]
Resolution – Configuration Manager
Check that the configuration files are configured to use multicast