DataDirect Networks SFA™ OS 2.0.0 Release Notes Revision A1 | 6
Issue 'SHOW ENCLOSURE <x> ALL' to identify your current BMC version. For
example, see Figure 2.
$ show enclosure 0 all
************************
* Enclosure(s) *
************************
Index: 0
Enclosure: 0x50000000
Type: CONTROLLER
Logical ID: 0x0001ff0900160000
Vendor ID: DDN
Product ID: SFA12000
Revision: 0000
Is Responsive: TRUE
Fault Status: OK
Child Fault Status: NON-CRITICAL
Zones: 0
Zoning Configuration: 0
Position: NOT APPLICABLE
Fault Indicator: OFF
Predicted Failure Ind: OFF
Locate Indicator: OFF
Baseboard part number: X9DRX+-F-DD007
Baseboard serial number:WM21S31110
Baseboard date: 19960101
BIOS version: 21.0k
BMC version: 21.67
Firmware version: 1.5.1.2
Total Enclosures: 1
Figure 2
2.5 Post-Firmware-Upgrade Procedure
SFA12K-40, SFA12K-20, SFA12K-20E, and SFA10K
After upgrading the firmware, perform these steps to initialize the battery life remaining
feature:
1. Issue the command, SHOW UPS * ALL_ATTRIBUTES.
2. If you see a date in “Battery Mfg. Date”, do nothing more.
3. If you see the message shown in Figure 3, then issue the command, CLEAR
CONTROLLER x UPS_HISTORY, where “x” is eitherlocal” or “remote” depending on
which UPS needs to be cleared.
Battery Mfg. Date: NOT AVAILABLE
Battery Life Remaining: NOT AVAILABLE
Figure 3