DataDirect Networks SFA™ OS 1.5.3.0 Release Notes Revision B | 8
2.5 Post-Firmware-Upgrade Procedure
2.5.1 SFA12K-40, SFA12K-20, SFA12K-20E, and SFA10K
After upgrading the firmware, perform these steps to initialize the battery life remaining
feature:
1. Issue the command, SHOW UPS * ALL_ATTRIBUTES.
2. If you see a date in “Battery Mfg. Date”, do nothing more.
3. If you see the message shown in Figure 5, then issue the command, CLEAR
CONTROLLER x UPS_HISTORY, where “x” is eitherlocal” or “remote” depending on
which UPS needs to be cleared.
Battery Mfg. Date: NOT AVAILABLE
Battery Life Remaining: NOT AVAILABLE
Figure 5
4. Issue the command, SHOW UPS * ALL_ATTRIBUTES. You should see the message
shown in Figure 6.
Battery Mfg. Date: Thu Sep 8 4:10:30 2011
Battery Life Remaining: 730 days
Figure 6
2.5.2 S2A6620
After upgrading the firmware, perform these steps to initialize the battery life remaining
feature:
1. Issue the command, SHOW UPS * ALL_ATTRIBUTES.
2. If you see a date in “Battery Mfg. Date” or you have a 6620 Li-Ion battery, do nothing
more.
Battery Mfg. Date: NOT AVAILABLE
Battery Life Remaining: NOT AVAILABLE
Figure 7
3. Issue the command, CLEAR CONTROLLER x UPS_HISTORY, where “x” is either “local
or “remotedepending on which UPS needs to be cleared.
4. Issue the command, SHOW UPS * ALL_ATTRIBUTES. You should see output similar to
that shown in Figure 8.
Battery Mfg. Date: Thu Sep 8 4:10:30 2011
Battery Life Remaining: 730 days
Figure 8